Factory: Uthiramerur, Tamil Nadu Warehouse: Vijayawada, Andhra Pradesh
Fenplast UPVC Profile logo
Fenplast system · 4 profiles

uPVC Ventilator

Compact uPVC ventilators for bathrooms, toilets and kitchens — with louvres, fixed glass or an exhaust-fan panel.

uPVC Ventilator — Fenplast profile assembly section drawing
About this system

How it’s built

Ventilators are small, but they sit in the wettest, most humid openings of the house. Wooden and steel ventilators rot or rust within a few monsoons; uPVC ventilators don’t.

The Fenplast ventilator combines the casement frame FEN-CF-011 and bead FEN-CB-015 with the ventilator frame FEN-AO-018. Use the louver bead FEN-AO-022 when glass or uPVC louvres are required, or fit a panel with an exhaust-fan cut-out.

Best suited for

  • Bathrooms and toilets
  • Kitchens with exhaust fans
  • Stairwells and lofts
  • Store and utility rooms
Bill of profiles

Profiles required

Order these Fenplast part codes to fabricate a ventilator. Steel reinforcement, gaskets and hardware are added during fabrication.

Part codeProfileRole in the systemWidthQty / bundle
FEN-AO-018Ventilator FrameVentilator frame50 mm10 nos
FEN-CF-011Casement FrameOuter frame57.5 mm6 nos
FEN-CB-015Casement Single BeadGlazing bead35 mm20 nos
FEN-AO-022Louver BeadLouver bead (option)48.5 mm12 nos
FAQ

uPVC Ventilator — FAQ

Can an exhaust fan be fitted in a uPVC ventilator?

Yes. A panel with a fan cut-out is fixed within the ventilator frame.

Which profiles make a louvred ventilator?

Ventilator frame FEN-AO-018 with louver bead FEN-AO-022, inside casement frame FEN-CF-011.

Are uPVC ventilators waterproof?

uPVC does not absorb water or corrode; correct sealing at installation keeps the ventilator weather-tight.

Hardware & glazing

Completing the ventilator

Profiles set the shape; hardware and glass decide how the ventilator feels and performs every day.

ComponentRecommendation
LouvresGlass or uPVC blades held with FEN-AO-022
Fan panelSolid panel with circular cut-out
Fixed glassFrosted, held with FEN-CB-015
FixingSealed perimeter to keep water out
Fabrication

Mistakes to avoid

The issues our technical team sees most often on ventilators — and every one is preventable.

  • Exhaust fan ducted into a closed shaft
  • Louvres facing the wrong way and letting rain in
  • Unsealed perimeter in wet walls
  • Ventilator too small for the bathroom

Further reading

More answers

Fabricator questions

Can a ventilator combine a fan and louvres?

Yes — a common layout has a fan panel on one side and louvres or frosted glass on the other.

Which way should louvres face?

Angled downward to the outside so rain runs off and doesn’t enter.

Planning a project or stocking up for the season?

Send us your profile list, quantities and delivery location. Our sales desk replies with availability, bundle-wise pricing and dispatch timelines within one working day.