Most uPVC window leaks come from installation and fabrication, not the profile: gaps between frame and wall, blocked or missing drainage slots, a missing or poorly fitted interlock, worn or badly fitted gaskets, poor corner welds, a sill that slopes towards the room, or sliders used on very exposed elevations. Each has a straightforward fix.
Every October, as the north-east monsoon reaches Chennai, our technical team takes calls about leaking windows. When we visit, we almost never find a cracked profile. We find gaps in the wall, blocked drainage, missing interlocks and sills that slope the wrong way. The good news: nearly every one of these is fixable.
First, where is the water coming from?
Before fixing anything, find the path. Water that appears at the bottom corner of a frame may have entered at the top of the wall. Use a hose test: with the window closed, spray steadily from outside, starting at the sill and moving up in sections, while someone watches inside. Note exactly where water first appears.
| Where water appears | Likely cause |
|---|---|
| Between frame and wall | Perimeter sealing gap |
| Inside the sliding track, overflowing | Blocked or missing drainage |
| Down the centre of a slider | Missing or poor interlock |
| Around the glass | Gasket or bead problem |
| At a welded corner | Poor weld or cleaning |
| Below the window on the wall | Sill slope or chajja issue |
1. Gaps between frame and wall
This is the most common cause by far. The frame sits in an opening that is never perfectly straight; the gap around it must be packed and sealed. If the gap is left open, filled only with loose mortar, or sealed with a thin smear of silicone, water finds its way in.
Fix: rake out loose material, fill deeper gaps properly, then run a continuous bead of quality exterior silicone around the outside of the frame. Seal the inside too for air-tightness.
2. Blocked or missing drainage
Sliding tracks will always collect some water. A well-made frame has slots routed in the outer face so that water drains outside. If the slots weren’t routed, are on the wrong face, or are clogged with dust and construction debris, the track fills and overflows into the room.
Fix: clear existing slots with a thin wire; if none exist, a fabricator can rout them in place. Make sure they open to the outside, below the lowest point of the track.
3. Missing or poorly fitted interlock
On sliding windows, the two shutters meet in the middle. Without an interlock — such as Fenplast’s FEN-SI-009 — that meeting line is a straight gap that wind will drive rain through.
Fix: fit the correct interlock to both meeting stiles with the right brush seal. For sliding doors, use the taller door interlock FEN-SI-010.
4. Gaskets and beads
Glazing gaskets seal the glass to the sash; on casements, sash gaskets seal the sash to the frame. Gaskets that are stretched during fitting shrink back and leave gaps at the corners. Beads that aren’t fully clipped leave a channel for water.
Fix: replace shrunken gaskets without stretching, and check every bead is fully engaged.
5. Weak or poorly cleaned welds
A good weld is continuous and watertight. A weld made at the wrong temperature or pressure can leave a hairline gap; over-aggressive corner cleaning can cut into the weld.
Fix: minor gaps can be sealed; a badly welded sash should be remade. This is also why buying consistent profiles matters — inconsistent bars produce inconsistent welds.
6. Sill and chajja details
The window can be perfect and the wall below can still leak if the sill slopes towards the room or the chajja (sunshade) above directs water onto the frame head.
Fix: the external sill should slope outwards with a drip groove underneath. Check that water from the chajja falls clear of the window.
7. The wrong system for the exposure
A well-made slider handles normal rain. On a high floor facing open sea during a cyclone, wind pressure can push water past brush seals. For the most exposed elevations, a casement window that compresses onto gaskets is the better choice.
A pre-monsoon checklist
- Check perimeter silicone for cracks or gaps; reseal where needed.
- Clear sliding tracks and drainage slots.
- Check interlocks and brush seals are in place.
- Look for shrunken gaskets at glass corners.
- Make sure locks pull shutters fully closed.
- Check sills and chajjas outside.
For fabricators: prevent the callback
Every leak callback costs you a site visit and some reputation. Build these into your process:
- Rout drainage on every sliding frame and check it before dispatch.
- Fit interlocks on every slider, without exception.
- Set gaskets without stretching.
- Seal the perimeter outside and inside on every installation.
- Do a hose test on at least one window per site before handover.
When it really is the profile
Rarely, a profile can be at fault — a split chamber, a warped bar, or a section that doesn’t match its drawing. That’s why we test to IS 17953 and pack every bundle with protective tape. If you suspect a profile defect, keep an offcut from the same bundle and contact your supplier with the bundle label.
Frequently asked questions
Is it normal for water to collect in a uPVC sliding track?
Yes. Sliding tracks are designed to collect some water and drain it outside through slots in the outer face. Water staying in the track or entering the room means the drainage is blocked or missing.
Can a leaking uPVC window be repaired without replacing it?
Usually. Resealing the perimeter, clearing or adding drainage slots, refitting interlocks and replacing gaskets fix most leaks.
Why does my window leak only in heavy wind?
Wind pressure pushes water past brush seals and up through drainage paths. Interlocks, correct drainage and, on very exposed walls, a casement window solve this.
Who is responsible for a window leak — profile maker or fabricator?
It depends on the cause. Profile defects are rare; most leaks trace back to fabrication or installation, which is the fabricator’s responsibility.
How do I test a window for leaks?
Spray water steadily over the outside of the closed window for several minutes, starting low and working up, while someone watches inside.